Current Location: Home> Product Class> MTL> MTL5500>

MTL5517 2channel DI relay output + LFD alarm isolated barrier

  • Product Name:MTL5517 2channel DI relay output + LFD alarm isolated barrier
  • Product Number:MTL5517
  • Brand:MTL
  • Views:181
你添加了1件商品 查看购物车
简单介绍
MTL5517 2channel DI relay output + LFD alarm isolated barrier MTL5517 2channel DI relay output + LFD alarm isolated barrier MTL5517 2channel DI relay output + LFD alarm isolated barrier

MTL5517 2channel DI relay output + LFD alarm isolated barrier

的详细介绍

Product overview

MTL5517 2channel DI relay output + LFD alarm isolated barrier

         MTL5517  2 channel DI relay output + LFD alarm isolated barrier

            

MTL5517  product specification as below for your reference.

MTL5517 2channel DI relay output + LFD alarm isolated barrier

MTL4517 – MTL5517 SWITCH/ PROXIMITY DETECTOR INTERFACE 2-channel, line fault detection, phase reversal

The MTLx517 enables two safe-area loads to be controlled, through a relay, by proximity detectors or switches located in a hazardous area. Line faults are signalled through a separate relay and indicated on the top of the module. Switches are provided to select phase reversal and to enable the line fault detection.

SPECIFICATION

MTL5517 2channel DI relay output + LFD alarm isolated barrier

SPECIFICATION
See also common specification
Number of channels
Two
Location of switch
Zone 0, IIC, T6 hazardous area
Div.1, Group A, hazardous location
Location of proximity detector
Zone 0, IIC, T4–6 hazardous area, if suitably certified
Div.1, Group A, hazardous location
Hazardous-area inputs
Inputs conforming to BS EN60947–5–6:2001 standards for
proximity detectors (NAMUR)
Voltage applied to sensor
7 to 9V dc from 1kΩ ±10%
Input/output characteristics
Normal phase
Outputs closed if input > 2.1mA (< 2kΩ in input circuit)
Outputs open if input < 1.2mA (> 10kΩ in input circuit)
Hysteresis: 200µA (650Ω) nominal
Line fault detection (LFD) (when selected)
User selectable by switches on the side of the module.
Line faults are indicated by the LED for each channel.
Line fault relay is energised and channel output relay de-energised
if input line-fault detected
Open-circuit alarm on if Iin < 50µA
Open-circuit alarm off if Iin > 250µA
Short-circuit alarm on if Rin < 100Ω
Short-circuit alarm off if Rin > 360Ω
Note: Resistors must be fitted when using the LFD facility with a contact input
500Ω to 1kΩ in series with switch
20kΩ to 25kΩ in parallel with switch
Safe-area output
Channel: Two single-pole relays with normally open contacts
LFD: Single pole relay with changeover contact (MTL4517)
Single pole relay with normally open contact (MTL5517)
Note: reactive loads must be adequately suppressed
Maximum current consumption
35mA at 24V
Power dissipation within unit
0.84W at 24V
LED indicators
Green: power indication
Yellow: two: channel status, on when output energised
Red: two: LFD indication, on when line fault detected
Safety description (each channel)
Uo=10.5V Io=14mA Po=37mW Um = 253V rms or dc


Other  related models for MTL5500 range as below

MTL5517 2channel DI relay output + LFD alarm isolated barrier


MTL5018AC

MTL5501-SR

MTL5510

MTL5510B

MTL5511

MTL5513 

MTL5514

MTL5514D

MTL5516C

MTL5517

MTL5521

MTL5522

MTL5523

MTL5523V – V

MTL5524

MTL5525

MTL5526

MTL5541

MTL5541A

MTL5541AS 

MTL5541S

MTL5544

MTL5544A

MTL5544AS

MTL5544D

MTL5544S

MTL5546

MTL5546Y

MTL5549

MTL5549Y

MTL5573

MTL5575

MTL5576-RTD

MTL5576-THC

MTL5581

MTL5582

MTL5582B

MTL5991 

MTL5531

MTL5532

MTL5533

MTL5561

MPA5500

MTL5051

MTL5053

MTL5314

MTL5599 

MTL5517 2channel DI relay output + LFD alarm isolated barrier

If  you have any other question about MTL5517, please feel free to contact me here.


Contact details

HONGKONG XIEYUAN TECH CO., LIMITED

Telephone:86-027-85508558

Mobile :86-15871691193(Whatapp&Wechat is available)

Skype:xyautomation

E-mail:sales1@hkxytech.com


 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd