MTL5541 1 channel 2/3 wire Transmitter repeater safety barrier
- Product Name:MTL5541 1 channel 2/3 wire Transmitter repeater safety barrier
- Product Number: MTL5541
- Brand:MTL
- Views:267
-
MTL5541 1 channel 2/3 wire Transmitter repeater safety barrier
的详细介绍Product overview
MTL5541 1 channel 2/3 wire Transmitter repeater safety barrier
MTL5541 1 channel 2/3 wire Transmitter repeater safety barrier
MTL5541 product specification as below
MTL5541 1 channel 2/3 wire Transmitter repeater safety barrier
MTL4541/S – MTL5541/S REPEATER POWER SUPPLY 4/20mA, HART®, 2- or 3-wire transmitters The MTLx541 provides a fully-floating dc supply for energising a conventional 2- or 3-wire 4/20mA transmitter, which is located in a hazardous area, and repeats the current in another floating circuit to drive a safe-area load. For HART 2-wire transmitters, the unit allows bi-directional communications signals superimposed on the 4/20mA loop current. Alternatively, the MTLx541S acts as a current sink for a safe-area connection rather than driving a current into the load. Separately powered current sources, such as 4-wire transmitters, can be connected but will not support HART communication.
SPECIFICATION
MTL5541 1 channel 2/3 wire Transmitter repeater safety barrier
See also common
specification
Number of
channels
One
Location of
transmitter
Zone 0, IIC,
T4–6 hazardous area if suitably certified
Div. 1, Group A
hazardous location
Safe-area
output
Signal range: 4
to 20mA
Under/over-range:
0 to 24mA
Safe-area load
resistance (MTLx541)
@ 24mA: 0 to
360Ω
@ 20mA: 0 to
450Ω
Safe-area load
(MTLx541S)
Current sink:
600Ω max.
Maximum voltage
source: 24V dc
Safe-area
circuit output resistance: > 1MΩ
Safe-area
circuit ripple
< 50µA
peak-to-peak
Hazardous-area
input
Signal range: 0
to 24mA (including over-range)
Transmitter
voltage: 16.5V at 20mA
Transfer
accuracy at 20°C
Better than
15µA
Temperature
drift
< 0.8µA/°C
Response time
Settles to
within 10% of final value within 50µs
Communications
supported
HART (terminals
1 & 2 only)
LED indicator
Green: power
indication
Maximum current
consumption (with 20mA signal)
51mA at 24V
Power
dissipation within unit (with 20mA signal)
MTLx541 0.7W @
24V dc
MTLx541S 1.0W @
24V dc
Safety
description
Terminals 2 to
1 and 3:
Uo=28V Io=93mA
Po=651mW Um = 253V rms or dc
Terminals 1 to
3:
Simple
apparatus ≤1.5V, ≤0.1A and ≤25mW; can be connected
without further
certification into any IS loop with an open-circuit
voltage <28V
Other related models for MTL5500 range as below
MTL5541 1 channel 2/3 wire Transmitter repeater safety barrier
MTL5018AC
MTL5501-SR
MTL5510
MTL5510B
MTL5511
MTL5513
MTL5514
MTL5514D
MTL5516C
MTL5517
MTL5521
MTL5522
MTL5523
MTL5523V – V
MTL5524
MTL5525
MTL5526
MTL5541
MTL5541A
MTL5541AS
MTL5541S
MTL5544
MTL5544A
MTL5544AS
MTL5544D
MTL5544S
MTL5546
MTL5546Y
MTL5549
MTL5549Y
MTL5573
MTL5575
MTL5576-RTD
MTL5576-THC
MTL5581
MTL5582
MTL5582B
MTL5991
MTL5531
MTL5532
MTL5533
MTL5561
MPA5500
MTL5051
MTL5053
MTL5314
MTL5599
MTL5541 1 channel 2/3 wire Transmitter repeater safety barrier
If you have any other question, please be free to contact me here.
Contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-027-85508558
Mobile :86-15871691193(Whatapp&Wechat is available)
Skype:xyautomation
E-mail:sales1@hkxytech.com