Current Location: Home> Product Class> MTL> MTL5500>

MTL5532 1channel pulse isolators, digital or analogue output

  • Product Name:MTL5532 1channel pulse isolators, digital or analogue output
  • Product Number:MTL5532
  • Brand:MTL
  • Views:209
你添加了1件商品 查看购物车
简单介绍
MTL5532 1channel pulse isolators, digital or analogue output MTL5532 1channel pulse isolators, digital or analogue output MTL5532 1channel pulse isolators, digital or analogue output

MTL5532 1channel pulse isolators, digital or analogue output

的详细介绍

Product overview

MTL5532 1channel pulse isolators, digital or analogue output

           MTL5532  1channel pulse isolators, digital or analogue output

            

MTL5532 product specification as below

MTL5532 1channel pulse isolators, digital or analogue output

MTL4532 – MTL5532 PULSE ISOLATOR pulse & 4/20mA current outputs

The MTLx532 isolates pulses from a switch, proximity detector, current pulse transmitter or voltage pulse transmitter located in a hazardous area. It is ideal for applications involving high pulse rates and fast response times, by repeating the pulses into the safe area. An analogue output proportional to frequency is also provided, together with a relay output, which may be configured to act as an alarm. Configuration is carried out with a personal computer.

SPECIFICATION

MTL5532 1channel pulse isolators, digital or analogue output

See also common specification

Number of channels

One, fully floating

Sensor type

Switch or proximity detector (NAMUR/BS EN 60947–5–6:2001)

2– or 3–wire voltage or pulse transmitter

Location of switch

Zone 0, IIC, T6 hazardous area

Div. 1, Group A, hazardous location

Location of proximity detector or transmitter

Zone 0, IIC, T4–T6 if suitably certified

Div.1, Group A, hazardous location

Input

Switch input:

Output ON if switch is closed

Proximity detector input:

Excitation: 7.0 to 9.0V dc from 1kΩ nominal

Output ON if input > 2.1mA* (< 2kΩ)

Output OFF if input < 1.2mA* (> 10kΩ)

Switching hysteresis: 0.2mA (650Ω) nominal

*NAMUR and BS EN 60947–5–6:2001standards

Current pulse input:

Transmitter supply: 16.5V dc at 20mA

Short circuit current: 24mA

Output: Iin > 9.0mA = ON, Iin < 7.0mA = OFF

Switching hysteresis: 0.5mA

Voltage pulse input

Input impedance: > 10kΩ

Switching point voltage (Vsp): 3, 6, or 12V nominal

(User selectable by switches on the side of the module)

Output: Vin > Vsp = ON, Vin < Vsp = OFF

Switching hysteresis: 100mV + (0.1 x Vsp) typical

Safe-area pulse output

Maximum delay: 10µs

Maximum off–state voltage: 35V

Maximum off–state leakage current: 10µA

Maximum on–state resistance: 25Ω

Maximum on–state current: 50mA

Output OFF if supply fails

Note: LFD signal is Zener-diode protected against inductive loads

Safe-area current output

Input capture delay: 2 signal periods (5ms min.)

Signal range: 4 to 20mA

Under/over range: 0 to 22mA

Load resistance: 0 to 450Ω @20mA

Output resistance: >1MΩ

Ripple: < 50µA peak-to-peak

Accuracy: better than 20µA at 20°C

Temperature drift: < 1µA/°C

Risetime (10% - 90%, after step change): 60 ms

Alarm output

Relay ON in alarm, 0.5A @ 35Vdc max.

 

Pulse width

High: 10µs min

Low: 10µs min

Frequency range

0 – 50kHz - pulse output mode

0 – 10KHz - for analogue output

LED indicators

Green: power indication

Yellow: on when output circuit is on

Red: flashing when line fault or error

Power requirement

65mA at 24V dc

70mA at 20V dc

55mA at 35V dc

Power dissipation within unit

1.35W maximum at 24V

1.75W maximum at 35V

Safety description (Um = 253V rms or dc)

Terminals 2 to 1 and 6 to 1

Uo=10.5V Io=14mA Po=37mW

Terminals 4 to 3 and 1

Uo=28V Io=93mA Po=651mW

Terminals 3 to 1

Non-energy-storing apparatus ≤1.5V, ≤0.1A and ≤25mW; can be

connected without further certification into any IS loop with an opencircuit

voltage <28V

Terminals 5 to 4 and 1

Vmax ≤ 28V, Imax ≤ 94mA, Pmax ≤ 0.66W

Configurator

A personal computer running MTL PCS45 software with a

PCL45USB serial interface.


MTL5532 1channel pulse isolators, digital or analogue output

Other related models for MTL5500 range as below 

MTL5018AC

MTL5501-SR

MTL5510

MTL5510B

MTL5511

MTL5513 

MTL5514

MTL5514D

MTL5516C

MTL5517

MTL5521

MTL5522

MTL5523

MTL5523V – V

MTL5524

MTL5525

MTL5526

MTL5541

MTL5541A

MTL5541AS 

MTL5541S

MTL5544

MTL5544A

MTL5544AS

MTL5544D

MTL5544S

MTL5546

MTL5546Y

MTL5549

MTL5549Y

MTL5573

MTL5575

MTL5576-RTD

MTL5576-THC

MTL5581

MTL5582

MTL5582B

MTL5991 

MTL5531

MTL5532

MTL5533

MTL5561

MPA5500

MTL5051

MTL5053

MTL5314

MTL5599 

MTL5532 1channel pulse isolators, digital or analogue output


If you have any other question about MTL5532, please feel free to contact me here!

Contact details

HONGKONG XIEYUAN TECH CO., LIMITED

Telephone:86-027-85508558

Mobile :86-15871691193(Whatapp&Wechat is available)

Skype:xyautomation

E-mail:sales1@hkxytech.com


 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd