Product overview

MTL5533 2channel vibration probe interface isolated barrier  


           MTL5533  2channel vibration probe interface isolated barrier

           

MTL5533 product specification as below

MTL5533 2channel vibration probe interface isolated barrier

MTL5533 VIBRATION TRANSDUCER INTERFACE 2-channel

The MTL5533 repeats signals from vibration sensors in a hazardous area, providing outputs for a monitoring system in the safe area. The interface is compatible with 3-wire eddy-current probes and accelerometers or 2-wire current sensors, the selection is made by switches on the side of the module.

SPECIFICATION

MTL5533 2channel vibration probe interface isolated barrier

See also common specification

Number of channels

Two

Sensor type

2- or 3-wire vibration transducer

Location of signal source

Zone 0, IIC, T4–6 hazardous area if suitably certified

Div. 1, Group A hazardous location

Hazardous-area input

Input impedance

(terminals 2 & 3, 5 & 6): 10kΩ

Transducer supply current, 2-wire

3.3mA (nom.) for 2-wire sensors, user selectable by switch

Signal range

Minimum –20V, maximum –0.5V

DC transfer accuracy at 20°C

<±50mV

AC transfer accuracy at 20°C

0Hz to 1kHz: ±1%

1kHz to 10kHz: –5% to +1%

10kHz to 20kHz: –10% to +1%

Temperature coefficient

±50ppm/°C (10 to 65°C)

±100ppm/°C (–20 to 10°C)

Voltage bandwidth

–3dB at 47kHz (typical)

Phase response

<14µs, equivalent to:

–1° at 200Hz

–3° at 600Hz

–5° at 1kHz

–50° at 10kHz

–100° at 20kHz

Safe-area output impedance

<20Ω

LED indicator

Green: power indication

Supply voltage

20 to 35V dc

Maximum current consumption (10mA transducer load/ch)

130mA at 24V

Maximum power dissipation within unit

2.7W

Safety description

Terminals 3 to 1 and 6 to 4

Uo=26.6V Io=94mA Po=0.66W Um = 253V rms or dc

Terminals 3 to 2 and 6 to 5

Non-energy-storing apparatus ≤1.5V, ≤0.1A and ≤25mW

MTL5533 2channel vibration probe interface isolated barrier

Other related model for MTL5500 range as below

MTL5018AC

MTL5501-SR

MTL5510

MTL5510B

MTL5511

MTL5513 

MTL5514

MTL5514D

MTL5516C

MTL5517

MTL5521

MTL5522

MTL5523

MTL5523V – V

MTL5524

MTL5525

MTL5526

MTL5541

MTL5541A

MTL5541AS 

MTL5541S

MTL5544

MTL5544A

MTL5544AS

MTL5544D

MTL5544S

MTL5546

MTL5546Y

MTL5549

MTL5549Y

MTL5573

MTL5575

MTL5576-RTD

MTL5576-THC

MTL5581

MTL5582

MTL5582B

MTL5991 

MTL5531

MTL5532

MTL5533

MTL5561

MPA5500

MTL5051

MTL5053

MTL5314

MTL5599 

MTL5533 2channel vibration probe interface isolated barrier


If you have any other question about MTL5533, please feel free to contact me here!

Contact detail


HONGKONG XIEYUAN TECH CO., LIMITED

Telephone:86-027-85508558

Mobile :86-15871691193(Whatapp&Wechat is available)

Skype:xyautomation

E-mail:sales1@hkxytech.com

 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd