Current Location: Home> Product Class> MTL> MTL5500>

MTL5561 2channel loop-powered, for fire and smoke detectors

  • Product Name:MTL5561 2channel loop-powered, for fire and smoke detectors
  • Product Number:MTL5561
  • Brand:MTL
  • Views:227
你添加了1件商品 查看购物车
简单介绍
MTL5561 2channel loop-powered, for fire and smoke detectors MTL5561 2channel loop-powered, for fire and smoke detectors MTL5561 2channel loop-powered, for fire and smoke detectors

MTL5561 2channel loop-powered, for fire and smoke detectors

的详细介绍

Product overview

MTL5561 2channel loop-powered, for fire and smoke detectors 

              MTL5561 2channel loop-powered, for fire and smoke detectors

               

MTL5561 product specification as below

MTL5561 2channel loop-powered, for fire and smoke detectors

MTL4561 – MTL5561 FIRE AND SMOKE DETECTOR INTERFACE 2-channel

The MTLx561 is a loop-powered 2–channel interface for use with conventional fire and smoke detectors located in hazardous areas. In operation, the triggering of a detector causes a corresponding change in the safe–area current. The unit features reverse input polarity protection.

SPECIFICATION

MTL5561 2channel loop-powered, for fire and smoke detectors

See also common specification

Number of channels

Two, fully floating, loop powered

Location of fire and smoke detectors

Zone 0, IIC, T4–6 hazardous area if suitably certified

Div. 1, Group A, hazardous area

Input voltage

6 to 30V dc

Current range

1 to 40mA, nominal

Quiescent safe–area current at 20°C

(hazardous–area terminals open circuit)

< 400µA at Vin = 24V per channel

Integral input polarity protection

Input circuit protected against reverse polarity

Minimum output voltage Vout at 20°C

For Vin ≤ 25V: Vout = Vin – (0.38 x current in mA) – 2V

For Vin > 25V: Vout = 22.5V – (0.35 x current in mA)

Maximum output voltage

28V from 300Ω

Transfer accuracy at 20°C

Better than 400µA

Temperature drift

< 4µA/°C ( 0°C to 60°C)

< 15µA/°C (–20°C to 0°C)

Response time to step input

Settles to within 5% of final value within 1.5ms

Power dissipation within unit

0.7W maximum at 24V with 40mA signal (each channel)

0.9W maximum at 30V with 40mA signal (each channel)

Safety description for each channel

Uo=28V Io=93mA Po=0.65W Um = 253V rms or dc

MTL5561 2channel loop-powered, for fire and smoke detectors


Other related models for MTL5500 range as below

MTL5018AC

MTL5501-SR

MTL5510

MTL5510B

MTL5511

MTL5513 

MTL5514

MTL5514D

MTL5516C

MTL5517

MTL5521

MTL5522

MTL5523

MTL5523V – V

MTL5524

MTL5525

MTL5526

MTL5541

MTL5541A

MTL5541AS 

MTL5541S

MTL5544

MTL5544A

MTL5544AS

MTL5544D

MTL5544S

MTL5546

MTL5546Y

MTL5549

MTL5549Y

MTL5573

MTL5575

MTL5576-RTD

MTL5576-THC

MTL5581

MTL5582

MTL5582B

MTL5991 

MTL5531

MTL5532

MTL5533

MTL5561

MPA5500

MTL5051

MTL5053

MTL5314

MTL5599 

MTL5561 2channel loop-powered, for fire and smoke detectors


If you have any other question about MTL5561, please feel free to contact me here.

Contact details

HONGKONG XIEYUAN TECH CO., LIMITED

Telephone:86-027-85508558

Mobile :86-15871691193(Whatapp&Wechat is available)

Skype:xyautomation

E-mail:sales1@hkxytech.com


 

Copy right © 2018 Power by www.yi-z.cn Management Portal
Contact Person: Jessica Yu;  Tel: 86-027-85508558  Fax: +86 027-85309780
Mobile: 86-15871691193 (Whatsapp & Telegram)  Email: sales1@hkxytech.com; Jackie@hkxytech.com   Skype: Jackie@hkxytech.com

link: www.isolatorbarrier.ltd