Overview
    Overview
	The MTLx510 enables four solid-state outputs in the safe area to be controlled by up to four switches or proximity detectors located in a hazardous area. Each pair of output transistors shares a common
	terminal and can switch +ve or –ve polarity signals. A range of module configurations is available (see Table 1) through the use of selector switches. When proximity detector modes are selected, LFD is enabled and the output switches to OFF if a line fault is detected.
MTL5510 SWITCH PROXIMITY DETECTOR INTERFACE MTL5510
	
		
	
        MTL5510 SWITCH PROXIMITY DETECTOR INTERFACE MTL5510
		SPECIFICATION
	
	
		See also common specification
	
	
		Number of channels
	
	
		4, configured by switches
	
	
		Location of switches
	
	
		Zone 0, IIC, T6 hazardous area
	
	
		Div 1, Group A hazardous location
	
	
		Location of proximity detectors
	
	
		Zone 0, IIC, T4-6 hazardous area if suitably certified
	
	
		Div 1, Group A, hazardous location
	
	
		Hazardous-area inputs
	
	
		Inputs conforming to BS EN60947–5–6:2001 standards for
	
	
		proximity detectors (NAMUR)
	
	
		Voltage applied to sensor
	
	
		7 to 9V dc from 1kΩ ±10%
	
	
		Input/output characteristics
	
	
		Normal phase
MTL5510 SWITCH PROXIMITY DETECTOR INTERFACE MTL5510
	MTL5510 SWITCH PROXIMITY DETECTOR INTERFACE MTL5510
		Outputs closed if input > 2.1mA (< 2kΩ in input circuit)
	
	
		Outputs open if input < 1.2mA (> 10kΩ in input circuit)
	
	
		Hysteresis: 200µA (650Ω) nominal
	
	
		Line fault detection (LFD) (when selected)
	
	
		User-selectable via switches on the side of the unit.
	
	
		Open-circuit alarm on if Iin < 50µA
	
	
		Open-circuit alarm off if Iin > 250µA
	
	
		Short-circuit alarm on if Rin < 100Ω
	
	
		Short-circuit alarm off if Rin > 360Ω
	
	
		Note: Resistors must be fitted when using the LFD facility with a contact input
	
	
		500Ω to 1kΩ in series with switch
	
	
		20kΩ to 25kΩ in parallel with switch
	
	
		Safe-area outputs
MTL5510 SWITCH PROXIMITY DETECTOR INTERFACE MTL5510
	MTL5510 SWITCH PROXIMITY DETECTOR INTERFACE MTL5510
		Floating solid-state outputs compatible with logic circuits
	
	
		Operating frequency: dc to 500Hz
	
	
		Max. off-state voltage: ± 35V
	
	
		Max. off-state leakage current: ± 50µA
	
	
		Max. on-state resistance: 25Ω
	
	
		Max. on-state current: ± 50mA
	
	
		LED indicators
	
	
		Green: power indication
	
	
		Yellow: four: on when output active
	
	
		Red: LFD indication + faulty channel’s yellow LED flashes
	
	
		Maximum current consumption
	
	
		40mA at 24V (with all output channels energised)
	
	
		Power dissipation within unit
	
	
		0.96W at 24V, with 10mA loads
	
	
		Safety description (each channel)
	
	
		Uo=10.5V Io=14mA Po=37mW Um = 253V rms or dc
MTL5510 SWITCH PROXIMITY DETECTOR INTERFACE MTL5510
Contact Information
Email address:Jackie@hkxytech.com jackie2018@126.com
Whatsapp:+86 15717178751
Skype:Jackie@hkxytech.com
Telegram:+86 15717178751
Phone:+86 15717178751
	MTL5510 SWITCH PROXIMITY DETECTOR INTERFACE MTL5510
Contact Information
Email address:Jackie@hkxytech.com jackie2018@126.com
Whatsapp:+86 15717178751
Skype:Jackie@hkxytech.com
Telegram:+86 15717178751
Phone:+86 15717178751
          RELATED PRODUCTS
      
         
     
     
                             
                             
                             
                             
                             
                             
                             
                             
                            